10. Removal Procedure
10.1 Removal Procedure of Indoor Unit
Warning Be sure to wait 10 minutes or more after turning
off all power supplies before disassembling work.
Removal Procedure
1.Disassemble Front Panel
2.Disassemble Filter and Press Plate
3.Disassemble Guide Louver
4.Disassemble Front Case
Push the convex parts in the left and right sides
of the front panel, and then lift the front panel.
Unscrew the screws fixing the display cover and
pull out the plug.Forcibly lift the front panel up-
wards from the clasps to take it out.
Top the middle section of air filter from the clasps
at both sides.Pull the air filter forward to remove
it.
Unscrew the 1 screw on press plate to open the
press plate.
Push out the axile bush in the middle of guide
louver .Then slightly bend the guide louver to
remove it.
Unscrew the 7 tapping screws fixing the front
case, and turn the front case backwards to re-
move it.
Press Plate
Clasps
Filter
Display Cover
Front
Panel
Guide Louver
Screw
screw