65
Installation and Maintenance
Service Manual
Terminals
screws
Step Procedure
Remove the screw xing the left and right drive
motor; disconnect the wiring terminal in the motor
and then remove the drive motor
5. Remove electric box assy
Remove the screw fixing electric box 3
,
Remove
the electric box 3.
Cut off the wire binder and pull out the
indoor tube temperature sensor.
Screw off two grounding screw.
Remove the room temperature sensor.
Remove the wiring terminals of motor, left&right
swing motor, up&down swing motor and out-
pushing mechanism motor
Wire binder
Grounding
screw
Indoor tube
temperature sensor
Room temperature
sensor
Wiring terminal
of motor
Terminal of left&right
swing motor
Terminals of up&down swing motor
and out-pushing mechanism motor
Terminals
screws
screw
Electric
Box 3

Related product manuals