12. Remove magnet coil
Remove the screw fixing the magnet coil and then
remove the coil.
magnet coil
13. Remove valves and 4-way valve subassembly
4- wa y valv e
14. Remove compressor
Remove the foot nuts on the compressor and then
remove the compressor.
compresso r
Unsolder welding joint connecting the capillary,
the valve and the outlet pipe of condenser to
remove the capillary. Do not block the capillary
with welding slag during unsoldering .
Remove the 2 screws fixing the gas valve and
unsolder the welding point between the gas valve
and the air-return pipe to remove the gas valve.
(NOTE: Discharge the refrigerant completely
before unsoldering; when unsoldering, wrap the
gas valve with a wet cloth completely to avoid
damage to the valve caused by high temperature) .
Remove the 2 screws fixing the liquid valve and
unsolder the welding joint connecting the liquid
valve to the Y-type pipe to remove the liquid valve.
Unsolder the welding joint connecting the 4-way
valve, the compressor and the condenser to
remove the 4-way valve.
liquid valv e
gas valv e
foot nuts