GREE ELECTRIC APPLIANCES,INC.OF ZHUHAI
Service Manual
MODEL:
(Refrigerant R410A)
GWC09KF-K3DNA5A GWC12KF-K3DNA5A
GWH09KF-K3DNA5A GWH12KF-K3DNA5A
GWH09KF-K3DNA6A GWH12KF-K3DNA6A
GWH09KF-K3DNB1A GWH12KF-K3DNB1A

Questions and Answers

  • Z
    zhangaprilAug 14, 2025
    Why is my Gree GWH12KF-K3DNA5A cooling/heating efficiency not good?
    • J
      Jonathan DominguezAug 14, 2025
      Check if the temperature setting is appropriate, inlet and outlet vents are unobstructed, the filter is clean, windows and doors are closed, the fan speed is not set to low, and there are no heat sources in the room.
  • A
    Andrew HowardAug 18, 2025
    Why is the wireless remote control not working for my Gree GWH12KF-K3DNA5A Air Conditioner?
    • D
      Desiree HopkinsAug 18, 2025
      If the unit is interfered with by abnormal or frequent function switchovers, unplug and reinsert the power plug. Also, ensure the remote is within range and not obstructed. Check the remote's battery voltage and replace the batteries if needed. If the remote is damaged, it may need replacement.
  • H
    Harold HunterAug 21, 2025
    Why is there water leakage in my Gree Air Conditioner outdoor unit?
    • R
      Ricky OlsenAug 21, 2025
      This can happen because the pipe and connection of the pipe would be condensed due to the water cooled down when the unit is running in COOL mode. Also, when the unit is running in Auto Defrosting mode the ice thawed and flowed out. Finally, when the unit is running in HEAT mode, the water adhered on the heat exchanger dripped off.
  • D
    Donald KellyAug 25, 2025
    Why is my Gree GWH12KF-K3DNA5A Air Conditioner compressor not turning on after turning it off for 3 minutes?
    • A
      Audrey TaylorAug 25, 2025
      The Gree Air Conditioner is designed to prohibit turning on the compressor for 3 minutes after it has been turned off.
  • R
    Robert WarrenAug 28, 2025
    How to fix Gree GWH12KF-K3DNA5A Air Conditioner not operating immediately after restarting?
    • A
      Anthony JohnsonAug 28, 2025
      After the air conditioner is stopped, it will not operate for approximately 3 minutes to protect itself.
  • S
    Samantha JonesAug 31, 2025
    Why does my Gree GWH12KF-K3DNA5A Air Conditioner indoor unit not deliver air?
    • A
      Amanda ParrishAug 31, 2025
      This can happen for a few reasons. When the temperature of the indoor heat exchanger is very low, the unit will stop delivering air to prevent cool air. Also, when the outdoor temperature is low or the humidity is high, frost can form on the outdoor heat exchanger, causing the unit to automatically defrost, during which the indoor unit will stop blowing air for 3-12 minutes. In dehumidifying mode, the indoor fan may stop to prevent condensed water from vaporizing again and to restrain temperature rising.
  • N
    Nicole LarsonSep 3, 2025
    What to do if there's a strange smell coming from my Gree GWH12KF-K3DNA5A?
    • E
      Erica ScottSep 3, 2025
      The smell may be accumulated in the ambient. Clean the filter. If the problem persists, the air conditioner needs cleaning, so contact an authorized maintenance center.
  • M
    Melanie RamosSep 6, 2025
    Why is there moisture on the air outlet vent of my Gree GWH12KF-K3DNA5A?
    • D
      Debra WrightSep 7, 2025
      If the unit is running under high humidity for a long time, moisture will condense on the air outlet grill and drip off.
  • C
    Crystal Richardson DVMSep 10, 2025
    What to do if my Gree GWH12KF-K3DNA5A unit cannot run?
    • B
      Beth FigueroaSep 10, 2025
      Check if the power has been shut down, the power plug is loose, the circuit protection device has tripped, the voltage is too high or low (tested by professionals), and the TIMER is correctly set.

Gree GWH12KF-K3DNA5A Specifications

General IconGeneral
Cooling Capacity3.5 kW
Power Supply220-240V, 50Hz
Indoor Unit Weight10 kg
TypeSplit System
Energy Efficiency Ratio (Cooling)3.5
Noise Level (Indoor)24 dB
Noise Level (Outdoor)50 dB
Dimensions (Outdoor Unit)780 x 540 x 320 mm
Indoor Unit Dimensions (WxHxD)800 x 290 x 200 mm
Outdoor Unit Dimensions (WxHxD)780 x 540 x 320 mm
Operating Temperature Range (Cooling)18°C to 43°C
Operating Temperature Range (Heating)-7-24 °C