15
Technical Information
Service Manual
2.2 Capacity Curve in Different Outdoor Temperature
2.3 Cooling and Heating Data Sheet in Rated Frequency
Heating
Rated heatling condition(°C)
(DB/WB)
Model
Pressure of gas pipe connecting
indoor and outdoor unit
Inlet and outlet pipe temperature
of heat exchanger
Fan speed of
indoor unit
Fan speed of
outdoor unit
Indoor Outdoor P (MPa) T1 (°C) T2 (°C)
20/- 7/6 07/09K 3.5~3.8
in:75~85
out:37~43
in:1~3
out:2~5
Super High High
20/- 7/6 12K 2.3~2.5
in:75~85
out:37~43
in:1~3
out:2~5
Super High High
40
50
60
70
80
90
100
110
32 33 34 35 36 37 38 39 40 41 42 43 44 45
Outdoor temp.( ) Outdoor temp.( )
)
%
(
o i t a r y t i c a p a
C
)%(oitar yticapaC
Condition
Indoor:DB27
°C
WB19
°C
°C
°C
Indoor air flow: Super High
Pipe length:5m
157-7 -5 02
24
0
20
40
60
80
100
120
-10510
Condition Heating
Indoor:DB20
°C
Indoor air flow: Super High
Pipe length:5m
Cooling Heating
Rated cooling condition(°C)
(DB/WB)
Model
Pressure of gas pipe connecting
indoor and outdoor unit
Inlet and outlet pipe temperature
of heat exchanger
Fan speed of
indoor unit
Fan speed of
outdoor unit
Indoor Outdoor P (MPa) T1 (°C) T2 (°C)
27/19 35/24 07/09K 0.85~1.0
in:8~11
out:11~14
in:75~85
out:37~43
Super High High
27/19 35/24 12K 0.9~1.1
in:8~11
out:11~14
in:75~85
out:37~43
Super High High
Cooling
Instruction:
T1: Inlet and outlet pipe temperature of evaporator
T2: Inlet and outlet pipe temperature of condenser
P: Pressure at the side of big valve
Connection pipe length: 5 m.