Service Manual
2. M alfunction o f B locked P ro tection o f IDU Fan M otor H6
Main detection points:
Smoothlyls the control terminal of PG motor connected tightly?
Smoothlyls the feedback interface of PG motor connected tightly?
The fan motor can't operate?
The motor is broken?
Detectioncircuit of the mainboard is defined abnormal?
Malfunction diagnosis process:
/-■''Under power-off condition>--
check whether the wiring terminal
between indoor fan and main
board is loose.
Reinsert the wiring
terminal of indoor fan.
Turn unit on "
to check whether the "
malfunction is
eliminated.
70
«
Installation and Maintenance
No