Service Manual
4. S tart-u p failu re (LC) (AP1 below m eans co ntrol board o f o u td o o r unit)
Main detection points:
If the compressor wiring is correct?
If the stop time of compressor is sufficient?
If the compressor is damaged?
If the refrigerant charging amount is too much?
The stop time is not sufficient and
the high and low pressure of system
is not balanced , please start the uni
after 3min
Check the connection situation
of outdoor mainboard A PI and
compressor COMP, and the
connect it according to wiring
diagram
Yes
/ Charge the refrigerant/
according to service
manual
No
_____
______
Replace outdoor
mainboard API
No
,
_____
N
_____
Replace the
compressor
Yes-
Yes-
End
78