6
2
.
3.
4.
5.
Remove the cable clamp, connect the connection cable 
and power cable with the terminal at the row of connection 
and fix the connection. The fitting line distributing must be 
consistent with the indoor unit terminal of line bank.
1.
Remove the handle at the right side plate of the
outdoor unit (ten screw).
Wiring should meet that of indoor unit.
Fix power connection wire by wire clamp.
Ensure wire has been fixed well.
Install the handle.
ELECTRICAL CONNECTIONS INSTALLER
GWHD(24)ND3CO
Wrong wire connection may cause malfunction of some 
electric components.After fixing cable, ensure that 
An all-pole disconnection switch having a contact
separation of at least 3mm in all pole should be 
connected in fixed wiring.
leads between connection to fixed point have some space.
The  connection  pipes  and  the  connectiong  wirings  of 
the unit A ,unit B and unit C must be corresponding to each 
other respective.
The  appliance  shall  be  installed  in  accordance  with 
national wiring regulations.
Do not  install the outdoor unit where it is exposed
to the sunlight.
Note:  the  above  figures  are  only  intended  to  be  a  simple 
 eht ot dnopserroc ton yam dna ecnailppa eht fo margaid
appearance of the units that have been purchased.
To the power supply
To unit B
To unit A
cable
connection
power
connection
cable
cable
To unit C
connection
cable
Outdoor unit
Indoor unit
L1
L2
L1
L1
L2
L2
 
Power
 
cable
A
B
C
D
connection cable
connection cable
connection cable
connection cable
1)    The power cable should be put in from the hole under
       connection cable cover. 
2)    If connecting with two indoor units, the connection cable
       should be put in from hole A and hole B.
3)    If connecting with three indoor units, the connection cable 
       should be put in from hole A , B and C.
4)    If connecting with four indoor units, the connection cable 
       should be put in from hole A, B , C and D.
 
All power cables and connection cables must be protected with conduits.