6
Technical Information
Service Manual
2.2 Operation Characteristic Curve
2.3 Capacity Variation Ratio According to Temperature
Cooling
Cooling
Heating
Heating
Cooling
Heating
24K
0
2
4
6
8
10
12
14
020406080100 120
0
2
4
6
8
10
12
14
020406080 100
120
Conditio
n
Indoor:DB 81°F
WB66
°F
Indoor air flow: Super High
Pipe length:24.6ft
Condition
Indoor:DB 68°F
Indoor air flow: Super High
Pipe length:24.6ft
Compressor Frequency(Hz)
Compressor Frequency(Hz)
Current(A)
Current(A)
Capacity ratio(%)
Capacity ratio(%)
Outdoor temp(°F)
89.695 100.4 107.6 118.4
60
70
80
90
100
110
120
50
40
40
50
120
110
100
90
80
70
60
50
44.63217.6-22-45
Outdoor temp(°F)
Condition
Indoor:DB81°F WB66°F
Indoor air flow: Super High
Pipe length:24.6 ft
Condition
Indoor:DB 68°F
Indoor air flow:Super High
Pipe length:24.6 ft