Service Manual
Safety Precautions for Installing
and Relocating the Unit:
Warnings
To ensure safety, please be mindful of the following precautions.
1. When installing or relocating the unit, be sure to keep the
refrigerant circuit free from air or substances other than the
specied refrigerant.
Any presence of air or other foreign substance in the refrigerant
circuit will cause system pressure rise or compressor rupture,
resulting in injury.
2.When installing or moving this unit, do not charge the
refrigerant which is not comply with that on the nameplate or
unqualied refrigerant.
Otherwise, it may cause abnormal operation, wrong action,
mechanical malfunction or even series safety accident.
3.When refrigerant needs to be recovered during relocating
or repairing the unit, be sure that the unit is running in
cooling mode.Then, fully close the valve at high pressure
side (liquid valve).About 30-40 seconds later, fully close the
valve at low pressure side (gas valve), immediately stop
the unit and disconnect power. Please note that the time for
refrigerant recovery should not exceed 1 minute.
If refrigerant recovery takes too much time, air may be sucked in
and cause pressure rise or compressor rupture, resulting in injury.
4.During refrigerant recovery, make sure that liquid valve and
gas valve are fully closed and power is disconnected before
detaching the connection pipe.
If compressor starts running when stop valve is open and
connection pipe is not yet connected, air will be sucked in and
cause pressure rise or compressor rupture, resulting in injury.
5.When installing the unit, make sure that connection pipe is
securely connected before the compressor starts running.
If compressor starts running when stop valve is open and
connection pipe is not yet connected, air will be sucked in and
cause pressure rise or compressor rupture, resulting in injury.
6.Prohibit installing the unit at the place where there may be
leaked corrosive gas or ammable gas.
If there leaked gas around the unit, it may cause explosion and
other accidents.
7.Do not use extension cords for electrical connections. If
the electric wire is not long enough, please contact a local
service center authorized and ask for a proper electric wire.
Poor connections may lead to electric shock or re.
8.Use the specied types of wires for electrical connections
between the indoor and outdoor units. Firmly clamp the
wires so that their terminals receive no external stresses.
Electric wires with insufcient capacity, wrong wire connections
and insecure wire terminals may cause electric shock or re.
45

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Gree LIVV12HP230V1AH and is the answer not in the manual?

Gree LIVV12HP230V1AH Specifications

General IconGeneral
ModelLIVV12HP230V1AH
Energy Efficiency Ratio (EER)12.0
RefrigerantR410A
Indoor Unit Noise Level42 dB(A)
TypeSplit System Air Conditioner
Cooling Capacity12, 000 BTU/h
Heating Capacity12000 BTU/h
Power Supply230V / 60Hz / 1Ph
Weight (Indoor Unit)22 lbs
Outdoor Unit Noise Level54 dB(A)

Related product manuals