MicroGuard
®
434/500 System — Troubleshooting Manual PN W453200 Rev C 08/01/00
GREER COMPANY 1918 E. Glenwood Place Santa Ana, CA 92705 Telephone: (714) 259-9702 FAX: (714) 259-7626
12 of 81
GREER COMPANY
GREER COMPANYGREER COMPANY
GREER COMPANY
Crane Systems
FAULT
CODE
FKO
POWER
FEED
A2B
POWER
FEED
DISPLAY
CONSOLE
ADC 2
INTERNAL
FAULT
ADC 1
INTERNAL
FAULT
ACTION
000
NONE
001
X
002
X
003
X X
004
X
Replace computer
005
X X
006
X X
007
X X X
008
X See SECTION 7
009
X X
010
X X
011
X X X
012
X X
Replace computer
013
X X X
014
X X X
015
X X X X
016
X Check crane circuit breakers, then
See SECTION 3.5.1
017
X X
018
X X
019
X X X
020
X X
Replace computer
021
X X X
022
X X X
023
X X X X
024
X X Check crane circuit breakers, then
See SECTION 3.5.1
025
X X X
026
X X X
027
X X X X
028
X X X
Replace computer
029
X X X X
030
X X X X
031
X X X X X
No Fault Found
2.3.2 GROUP “B” FAULT CODES
GROUP “B” FAULT CODES REPRESENT FAULTS DETECTED FOR INTERNAL ANALOG
FUNCTIONS AND POWER FEEDS TO THE FUNCTION KICKOUT AND ANTI-TWO BLOCK
SWITCHES.
The following chart details all of the available codes in the left column and the actions to take
in the right column.
SECTION 2