VSS 10-12
13
MAINTENANCE
Check and tighten all hose clamps.
Check for worn hoses. (rubbing, cracking)
Check Engine air filter, clean every 50 hours; change every year or 300 hours.
Check Engine oil with each use, change after 20 hours and every 100 hours thereafter.
Check Pump oil with each use, change every year or 500 hours.
Check Pump Gearbox oil with each use, change after 20 hours and every 100 hours
thereafter.
Clean Suction Strainer. (See photos 21 and 22)
SPECIFICATIONS
Engine Crankcase Oil ......................................................... 10W30 (SJ or SL)
Engine Fuel Recommendation ............................................ 86 Octane (Min) unleaded
Pump Crankcase Oil ........................................................... 30 Wt. or 40 Wt. Non-detergent
Pump Gearbox Oil .............................................................. 80W90 Gear Oil
Photo 21 Suction Strainer Photo 22 Center Post
The suction strainer is equipped with an internal shut-off valve that closes when the
cup is removed. It prevents the suction line from emptying when the strainer is
dissembled for cleaning.
IMPORTANT!
When re-assembling the strainer, ensure that the center post in the cup engages the
steel pin in the strainer head. (See photo 22) Otherwise, the valve will remain closed
and damage to the pump may result.