VSS 10-12
6
START-UP AND TESTING
1. Re-attach the hoses to any modular tanks that were disconnected for shipping.
Note: The hoses may be longer than necessary; trim to length as required.
2. Ensure that suction strainer bowl is on tight.
3. Fill the spray tank 1/4 full of clean water.
4. Put gas in engine gas tank.
5. Turn on fuel shut-off valve lever on the carburetor. (See photo 8)
Photo 8 Fuel Shut-off
6. Recheck the engine oil level and check the oil in the pump and gearbox.
7. Put regulator lever in the Bypass position. (See photos 9 and 11)
Photo 9 Kappa 43 Pressure Regulator Bypass Position Photo 10 Kappa 43 Pressure Regulator Spray Position
Photo 11 Kappa 40/55/75 Pressure Regulator Photo 12 Kappa 40/55/75 Pressure Regulator
Bypass Position Spray Position
Fuel Shut-off Valve lever