DOOR BEHAVIOUR
Setting door behaviour
To set the door behaviour modes, adjust the DIP
switches in the corner of the MCB shown.
DIP Switch 1 controls the latch option of the DOWN
direction while DIP Switch 2 controls the latch option of
the UP direction.
Latch up / Inch down (default):
The door will latch up, travelling
upwards with only a single press
and release of the UP button. The
door will stop at the set limit.
The door will inch down, only
travelling downwards when the
DOWN button is held. The door will
stop at the closed limit or when the
button is released.
Inch up / Inch down:
The door will inch up and inch
down, only travelling whilst the UP
or DOWN buttons are being held.
The door will stop at the limits or
when the button is released.
Latch up and down*:
The door will latch up and latch
down, travelling either upwards or
downwards with only a single press
and release of the UP or DOWN
buttons respectively. This
configuration must be set to enable
myQ Operation.
* The latch up and down mode is only possible when Entrapment Protection Devices such as an Infrared (IR) Beam or a Safety
Bump Edge habe been installed and are operating correctly. Failure to add Entrapment Protection Devices may result in damage to
property or injury to persons.
NOTE: The myQ Internet Gateway can only be learned when the door behaviour mode is set to Latch up and down and the
appropriate Entrapment Protection Devices have been installed and are operating correctly.
WARNING
MECHANICAL
Entrapment Protection
The Entrapment Protection System for your installation will be determined by the functional requirements of the door. To ensure the
installation meets these requirements refer to AS/NZS 60335-2-103.
When using the Grifco® Protector System as part of the Entrapment Protection System, ensure it is installed to detect a 100mm high
obstacle, i.e.; approximately 80mm from the floor, and in accordance with installation directions supplied.