Installation, Operation, and Maintenance
Manual
8106.082/.181 Matador

Questions and Answers

  • F
    Frank HillAug 13, 2025
    What to do if the motor protection trips on my Grindex Water Pump?
    • F
      Felicia YorkAug 13, 2025
      If your Grindex Water Pump runs but the motor protection trips, it could be due to a few reasons. The motor protection might be set too low; in this case, set it according to the data plate and cable chart if applicable. Additionally, if the impeller is difficult to rotate by hand, clean the impeller and the sump, and ensure the impeller is properly trimmed.
  • J
    James HarrisAug 18, 2025
    Why does my Grindex 8106.181 start and stop in rapid sequence?
    • L
      Laura HickmanAug 18, 2025
      If your Grindex Water Pump starts and stops rapidly, it could be due to back-flow causing the sump to refill to the start level. Ensure the distance between the start and stop levels is sufficient and that the non-return valves are functioning properly. Also, confirm that the length of the discharge pipe between the pump and the first non-return valve is sufficiently short. Alternatively, the self-holding function of the contactor may be malfunctioning. Check the contactor connections, the voltage in the control circuit in relation to the rated voltages on the coil, and the functioning of the stop-level regulator. Determine whether the voltage drop in the line at the starting surge causes the contactor's self-holding malfunction.
  • L
    Lindsey MyersAug 23, 2025
    What to do if my Grindex 8106.181 Water Pump doesn't stop when using a level sensor?
    • K
      Kenneth CookAug 23, 2025
      If your Grindex Water Pump doesn't stop when a level sensor is used, it could be because the pump can't empty the sump to the stop level. Check for leaks from the piping and discharge connection, ensure the impeller isn't clogged, and verify that the non-return valves are functioning properly. Another reason could be a malfunction in the level-sensing equipment, so clean the level regulators, check their functioning, check the contactor and the control circuit, and replace any defective items. Lastly, the stop level might be set too low, so raise it.
  • J
    Jack WilliamsSep 2, 2025
    How to fix a Grindex 8106.181 with SMART[™] or softstarter that won't start?
    • C
      Christina BennettSep 2, 2025
      If your Grindex Water Pump with SMART[™] or softstarter does not start, the phase sequence may be incorrect. To correct this: pull out the plug, then shift two phases by turning two contact pins with a screwdriver (do not take the plug apart), or turn the knob to the opposite position 1, with 8 seconds delay (do not reverse the phase sequence while the motor is running; doing so may cause incorrect rotation resulting in damages to the motor electronics and the rotating parts; respect the 8 seconds delay), or shift two phase conductors in the cabinet if no glove or phase shifter is used.
  • J
    Joseph BanksNov 7, 2025
    Why is my Grindex 8106.181 not delivering enough water?
    • J
      jennifer11Nov 7, 2025
      If your Grindex Water Pump delivers too little or no water, several factors could be at play. The impeller might be rotating in the wrong direction; if it is a 3-phase pump without SMART™, transpose two phase leads, or if it has a softstarter, transpose the leads at T1, T2, T3 on the softstarter. For pumps with SMART™, correct the internal wiring. One or more valves might be incorrectly positioned, so reset them, replace if needed, and ensure they are correctly installed according to media flow and open correctly. Also, check for obstructions in the pipes and clean them to ensure free flow. Address any leaks in pipes and joints by sealing them. Inspect the impeller, pump, and casing for wear and replace worn parts. Ensure the liquid level isn't too low by checking the level sensor setting....
  • D
    David PetersonNov 27, 2025
    Why won't my Grindex 8106.181 start?
    • B
      Brian SanchezNov 27, 2025
      If your Grindex Water Pump does not start, several issues could be the cause. An alarm signal might have been triggered on the control panel, so check that the impeller rotates freely, the sensor indicators do not indicate an alarm, and the overload protection is not tripped. The installation might not be receiving voltage; check that the main power switch is on, there is control voltage to the start equipment, the fuses are intact, there is voltage in all phases of the supply line, all fuses have power and are securely fastened, the overload protection is not tripped, and the motor cable is not damaged. The impeller could be stuck, so clean the impeller and the sump to prevent future clogs. If the pump does not start automatically but can be started manually, check that the start level re...

Summary

Safety Precautions

General Safety Warnings

Critical warnings for safe operation, installation, and maintenance of the unit.

General Safety Cautions

Cautions to observe for preventing injury, damage, or delays during product use.

User Safety Guidelines

Rules for ensuring personal safety when operating the pump.

Required Safety Equipment

Lists essential safety equipment to be used in the work area.

Transportation and Storage

Lifting Procedures

Safe methods and precautions for lifting the pump unit.

Product Description

Data Plate Information

Explains the data plate on the pump body listing key product specifications.

Installation

Installing the Pump

Step-by-step instructions for installing the pump unit, including safety precautions.

Pump Installation Steps

Steps for connecting the pump, including cable routing and lowering into the sump.

Electrical Connections

General Electrical Connection Precautions

Safety warnings and precautions for electrical work, including hazard identification.

Electrical Installation Requirements

General requirements for electrical installation, including mains voltage and fuse ratings.

Cable Installation Guidelines

Requirements for installing cables, ensuring they are in good condition and correctly fitted.

Earthing and Grounding

Critical safety information regarding proper earthing (grounding) of electrical equipment.

Connecting the Motor Cable

Step-by-step instructions for connecting the motor cable to the pump.

Cable Charts and Connection Locations

Diagrams and tables showing connection locations and cable chart details.

Motor Cable and Starter Unit Connections

Detailed diagrams for connecting motor cables and starter units to the terminal plate.

Check Impeller Rotation (Pumps without Built-in Motor Protection)

Impeller Rotation Warning

Warning about the powerful starting jerk when checking impeller rotation.

Check Phase Sequence (Pumps with Built-in Motor Protection)

Phase Sequence Warning

Warning about the powerful starting jerk when checking phase sequence.

Operation

Operational Precautions

General warnings and cautions for safe pump operation.

Starting the Pump

Safety DANGER notice before working on or starting the pump.

Pump Start-Up Warnings

Warnings regarding unit stability, hot liquids, and proximity during start-up.

Pump Start-Up Notices

Notices regarding correct impeller rotation and pre-start checks.

Maintenance

Maintenance Precautions

Safety precautions and requirements before performing maintenance on the unit.

General Maintenance Guidelines

Tasks to remember during maintenance and before reassembly.

Regular Inspection Procedures

Details service items and actions for regular inspection of the pump and peripheral equipment.

Changing the Oil

Filling with New Oil

Instructions for refilling the pump with oil to the correct level.

Replacing the Impeller

Removing the Impeller (N, H)

Steps to remove the impeller, including safety warnings for sharp edges.

Installing the Impeller (N, H)

Steps for installing the impeller, including shaft preparation and alignment.

Troubleshooting

Troubleshooting Introduction

DANGER notice about personal injury hazard when troubleshooting live panels.

General Troubleshooting Guidelines and Tools

Guidelines for safe troubleshooting, including power lockout and necessary tools.

Pump Does Not Start (SMART or Softstarter)

Troubleshooting for pumps not starting with SMART or softstarter, checking phase sequence.

Pump Start-Up Warning

Warning about the powerful starting jerk when checking impeller rotation.

Pump Start-Up Notice

Notice against overriding motor protection if it has tripped.

Pump Does Not Start

Troubleshooting steps when the pump fails to start.

Service Startup Prevention Warning

Warning to disconnect and lock out power before servicing to prevent unexpected startup.

Motor Protection Trip Notice

Notice against repeatedly overriding motor protection if it has tripped.

Pump Does Not Stop (Level Sensor)

Troubleshooting when the pump fails to stop correctly with a level sensor.

Level Sensor Stop Warning

Warning to disconnect and lock out power before servicing to prevent unexpected startup.

Sump Not Emptying to Stop Level

Checks for leaks, impeller clogging, non-return valve function, and pump capacity.

Pump Rapid Start-Stop Sequence

Troubleshooting rapid start-stop cycles caused by back-flow or contactor issues.

Pump Starts Due to Back-Flow

Checks for start/stop level distance, non-return valve function, and discharge pipe length.

Contactor Self-Holding Malfunction

Checks contactor connections, control circuit voltage, and voltage drop issues.

Pump Runs, Motor Protection Trips

Troubleshooting when the pump runs but motor protection trips.

Motor Protection Trip Warning

Warning to disconnect and lock out power before servicing to prevent unexpected startup.

Pump Delivers Too Little or No Water

Troubleshooting low or no water output from the pump.

Low Water Output Warning

Warning to disconnect and lock out power before servicing to prevent unexpected startup.

Softstarter Operation Warning

Warning to disconnect and lock out power before servicing to prevent unexpected startup.

Grindex 8106.181 Specifications

General IconGeneral
Model8106.181
CategoryWater Pump
Weight37 kg
Frequency50 Hz
Max. Flow12 m³/h
Max Flow Rate12 m³/h

Related product manuals