EasyManuals Logo
Home>Groen>Oven>CONVECTION COMBO CC-E series

Groen CONVECTION COMBO CC-E series User Manual

Groen CONVECTION COMBO CC-E series
32 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #10 background imageLoading...
Page #10 background image
OM-CC-E
10
and 410 kPa). A pressure regulator is required
above 60 PSI (410 kPa).
A ¾ inch (19 mm) NH (garden hose type)
connector is required to connect the water supply
to the water inlet valve. The water feed line
diameter may not be less that ½ inch (13 mm).
Use a washer (or if necessary, two washers) in
the hose connection. Do not allow the
connection to have any leak, no matter how
small.
4.
Drain Connection
CAUTION
DO NOT USE PLASTIC PIPE. DRAIN MUST BE
RATED FOR BOILING WATER.
WARNING
BLOCKING THE DRAIN IS HAZARDOUS.
IMPORTANT: Do not allow any water traps in the
line. A trap can cause pressure to build up
inside the cavity during steaming, which will
make the door gasket leak.
NOTE: Improper drain connection will void the
warranty.
CC20-E With Drain Tank
A two inch (51 cm) ID hose may be attached to
the supplied drain elbow with a clamp. The hose
may be connected directly to a building drain
since the drain tank has an air vent, which
eliminates the need for a free air gap at the
building drain.
Do not block the air vent in any way. Do not
attach anything to the vent or reduce its size.
Do NOT use plastic pipe in the drain line,
because the drain must withstand boiling water.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Groen CONVECTION COMBO CC-E series and is the answer not in the manual?

Groen CONVECTION COMBO CC-E series Specifications

General IconGeneral
BrandGroen
ModelCONVECTION COMBO CC-E series
CategoryOven
LanguageEnglish

Related product manuals