EasyManuals Logo

Groen CONVECTION COMBO CC-E series User Manual

Groen CONVECTION COMBO CC-E series
32 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #11 background imageLoading...
Page #11 background image
OM-CC-E
11
Initial Start-Up
WARNING
ANY POTENTIAL USER OF THE EQUIPMENT SHOULD BE TRAINED IN SAFE AND CORRECT OPERATING
PROCEDURES.
After the Convection Combo™ has been installed,
test it to ensure that it is operating correctly.
1.
Remove all literature and packing materials from
the interior and exterior of the unit.
2. Check that the cold water supply line is open and
that none of the fittings are leaking.
3.
Turn on electrical service to the unit.
4.
High Altitude Operation. At altitudes above
5,000 feet (1524m), the unit will not operate in
the Steamer or Combo Modes unless the altitude
is set. You can program the altitude as follows:
a. If the unit is on, turn it off by pressing the ON
touch pad.
b. Press and hold the STEAM touch pad while
turning the unit on by pressing the ON touch
pad. The Timer Display will show the letters
AL and a number representing the altitude in
thousands of feet. If the altitude has not
been set for your unit, the display will be 0.
c. Enter an altitude value between 0 and 15,
using the numbered touch pads. For
example, if the unit will be operating at 7,000
feet, enter 7.
d. Press the START touch pad.
Altitude Metric Conversion
Altitude
Setting
Feet Meters
5000 1524 5
6000 1830 6
7000 2133 7
8000 2438 8
9000 2745 9
10000 3048 10
11000 3353 11
12000 3658 12
13000 3962 13
14000 4267 14
15000 4572 15
5.
For CC20-E only: Check Fan
Rotation IMPORTANT! As
seen from inside the oven cavity,
the fan should be turning in a
counterclockwise direction. If the
fan is running backwards
(clockwise), have a qualified
electrician turn off the main power and switch
any two incoming power leads on the distribution
block. An incorrectly turning fan will eventually
shut the oven down.
6.
Select Farenheit or
Celsius
Temperatures. The
Convection Combo™
is delivered with the
Farenheit scale as
default. To change
the current
temperature scale,
holding the 5 key in,
press ON. The Timer
Display will either
show dEG°F or
dEG°C. Press the 5
key again to change
from one to the other. Press START to accept
the change.
7.
To Test Steamer Mode Operation, turn on the
unit. (For details of operating procedure, see the
Operation section of this manual.) Clear time
from the time display. Press the STEAM touch
pad. (If the HOT light is on, see the Fast Cool
instructions in the Operation section.)
The WAIT light will stay on while the steam
generator fills with and heats the water. The
WAIT light should turn off within three minutes,
and the READY light should come on. This
indicates that the water is at its standby
temperature. The timer only controls operations
in the Steamer Mode. Enter a time and press
START. (“Time is set in minutes and hours
only. Seconds are not displayed).
Examples: 2 minutes = 00:02
(Just press 2).
1 hour and 30 minutes = 01:30
(Press 1, 3, and 0, or press 9,0
the timer will change to 1:30)