58
Step 3: Installing the charging station
Once you have laid the boundary cable out around the
entire work area and you are at your start point, you can
connect the charging station.
The charging station must be positioned so that the “IN”
mark faces the work area.
The boundary cable that runs from the charging station
must be fed under the charging station so that its end
returns to the rear of the charging station. The other
end of the boundary cable must be fed to the rear of the
charging station.
Strip the ends of the boundary cable so that 10-15 mm
of wire is exposed.
The cable that comes in under the charging station
must be attached to the red clamp marked with a “+”.
The cable that does NOT come in under the charging
station must be attached to the black clamp marked
with a “S1”.
Note! Excess boundary cable must not be placed behind
the charging station!
10-15 mm
“IN”
(In towards the work area)