- 43 -
www.hzgrow.com
The main control downloads one fingerprint feature or template for accurate
comparison
The whole process mainly includes: download template and read template and accurate comparison.
BufferID is set to 1 when downloading template.
BufferID is set to 2 when reading template.
Start
Send download template command
Return successfully
Send data packet
Finish packet
Send read template command
Return successfully
Send accurate comparison command
Finish