reason can be
utility grid voltage
or frequency
change frequently.
3.If error message still exists, contact
Growatt.
1. Check PE ,to ensure that the PE
line contact good.
2. Check the L line and the N line to
ensure that they are not reversed.
3. Restart inverter .
4. If error message still exists, contact
Growatt.
Communication
fault. Master
processor can’t
receive data from
Slave processor.
1.Restart the inverter
2.If error message still exists, contact
Growatt.
Note
:
The latest 5 NS(Network and System) protection records can be read by LCD or
communication software. An interruption of ≤3 Sec to the power supply does not lead to any loss
of fault records (according to VDE-AR-N 4105, cl.6.5.1).
11 Manufacturer Warranty
Please refer to the warranty card.
12 Decommissioning
12.1 Dismantling the Inverter
1 Disconnect the inverter as described in section 8 .
2 Remove all connection cables from the inverter.
Danger of burn injuries due to hot enclosure parts!
Wait 5 minutes before disassembling until the housing has cooled down.
3 Screw off all projecting cable glands.