Growatt MAX 80KTL3 LV Specifications

General IconGeneral
ModelMAX 80KTL3 LV
Rated Power80 kW
Max. DC Input Voltage1100 V
Input Voltage Range200 V - 1000 V
Start Voltage200 V
Nominal DC Voltage600 V
Max DC Input Current per MPPT26A
Max. Input Current per MPPT26 A
Nominal AC Power80 kW
Max. AC Output Power80 kW
Nominal AC Voltage400 V
THDi< 3%
THD< 3%
DC SwitchYes
Protection ClassI
Overvoltage CategoryII
Operating Temperature Range-25 °C to +60 °C
Ingress ProtectionIP65
TopologyTransformerless
Efficiency98.6%
Protection LevelIP65
Max. DC Power120000W
Max. DC Input Power120000 W
MPPT Voltage Range200 V - 1000 V
Max. AC Apparent Power88 kVA
AC Voltage Range320 V - 480 V
Nominal Grid Frequency50 Hz
Humidity0-100%
CommunicationRS485
Grid Frequency Range47 Hz - 52 Hz (50 Hz) / 57 Hz - 62 Hz (60 Hz)
Power Factor0.8 leading - 0.8 lagging
Frequency Range47 Hz - 52 Hz (50 Hz) / 57 Hz - 62 Hz (60 Hz)

Summary

Overview

Applicable Personnel

Details requirements for qualified electrical technicians for installation, troubleshooting, and communication settings.

Safety Precautions

Safety Overview

Highlights general safety precautions for installation and handling of the inverter and its components.

Product Introduction

AFCI Detection Function

Describes the optional Arc Fault Circuit Interrupter function for fire prevention.

Anti-PID Function

Explains the optional function to mitigate Potential Induced Degradation in PV modules.

Installation

Basic Installation Requirements

Details essential requirements for safe and effective inverter installation, including wall, space, and environment.

Installation Environment Requirements

Specifies environmental conditions and placement guidelines to ensure optimal inverter performance and lifespan.

Wall Mount Bracket Installation

Guides on how to install the wall mount bracket, including drilling and securing the plate.

Installing The Inverter

Details the procedure for physically mounting the inverter onto the installed wall bracket.

Connecting Cables

Connection on AC side

Provides instructions and safety precautions for connecting the inverter to the AC power grid.

Connection On DC Side

Details the procedure and safety warnings for connecting the DC input from solar panels to the inverter.

Connecting The Ground Cables

Provides instructions for properly grounding the inverter and system components for safety.

System Commissioning

Commission The Inverter

Details the initial setup and configuration process for the inverter, including address and time settings.

Monitoring

Local Data Monitoring

Routine Maintenance

Trouble Shooting

Error Codes

Lists error codes, their descriptions, and suggested actions for troubleshooting inverter faults.