Growatt SPA 3000TL BL - U-disk Firmware upgrade

Growatt SPA 3000TL BL
32 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
39
40
Fig 6.16
Fig 6.17
Fig 6.18
Fig 6.19
different power, customer need to check the max power of battery.
Time setting is 24-hour. If the end time is less than beginning time, it defaults to
spanning days.
Under the MODE Change ,you can see the setup options below after pressing Enter
Power Rate is used to set up power of battery. So different battery may has the
NOTICE:
NOTICE:
The MODE change has two options which are sensor and battery types. In the sensor
types, you can choose cable CT default meter and SP-CT wireless RF transfer .In
the battery types you can chose lithium battery or lead-acid battery.
Under the default set ,you can see the setup options below after pressing Enter
Default set is “resume to default setting ”,please don't use it unless it's necessary.
User can upgrade inverter's firmware via the USB port use a U-disk.
Please contact Growatt service support to get the upgrade files, and extract into the U-
disk.
Warning: Don't modify the folder name or program file name, it may cause the upgrade
failed.
Unscrew the waterproof lid and insert U-disk into the USB port, the upgrade will begin
automatically.
The LCD will show Programming during upgrade, after finished, it will show
Program OK, and inverter will back to normal working state. Then pull out the U-disk,
and screw the waterproof lid.
6.5 Communication
6.5.1 U-disk Firmware upgrade
USB is only used for firmware update. Customer can't use it for charging.
WorkMode
Stop SOC: 100%
Stop SOC: 5%
WorkMode
Time
WorkMode
Power Rate: 100 %
Power Rate: 100 %
Priority
WorkMode
WorkMode
Opt: Load First default
Bat First
Grid First
WorkMode
WorkMode
WorkMode
00:00 00:00
WorkMode
Save OK
NO
WorkMode
Time
WorkMode
00:00 00:00
WorkMode
Save OK
NO
If battery first is
choosen
WorkMode
Bat First: ON
OFF
Range from 5 to 100%,
and the accuracy is 1%
Range from 10 to 100%,
and the accuracy is 1%
WorkMode
If Grid first is choosen
Grid First: ON
OFF
Range from 5 to 100%,
and the accuracy is 1%
Range from 10 to 100%,
and the accuracy is 1%
Press down
key to the next item
Press down
key to the next item
Choose ON
to the next item
Choose ON
to the next item
WorkMode
Time
WorkMode
00:00 00:00
WorkMode
Save OK
NO
WorkMode
If Load first is choosen
Discharge: ON
OFF
Press down
key to the next item
Choose OFF
to the next item
MODE Change
WorkMode
Sensor
WorkMode
Cable CT
WorkMode
Meter
SP-CT
Battery Type
WorkMode
Lithium
WorkMode
Lead-acid
Press “enter”
key to make sure
Press “down”
key to the next
item
Press
“enter” key
to make sure
Default Set
WorkMode
WorkMode
YES
Press “enter”
key to make sure
Press “enter” key more
than 3 seconds to make sure