Growatt SPF-3500ES - 53 Fault

Growatt SPF-3500ES
49 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
20
battery voltage. Then 52fault will occur
9 53 fault
Fig.7 53fault
Testing method:
Just connect the inverter to battery system, Switch on the inverter, if 53fault still occurs, it means DC-AC
circuit has the trouble. When AC output voltage reaches less than 230V and lasts for 20s. It will have the
error.
Solution:
For usual client, suggest replacing mainboard
For professional client, suggest deliverying some IGBT or Optocouplers to them and try to repair it.
Malfunction Reason:
Most of time, it is caused by DC-AC circuit, including IGBT, Driving circuit etc.
Repairing Method:
a. please kindly turn to diode position on multimeter.