39
9 15,16 warning
15,16 warning are related with parallel input utility.
Testing method:
b. Check if connection wire of utility input is installed correctly.
c. Check if utility input breaker is ok
Solution:
Try to replace utility input connection wire or breaker.
Part III. Battery Communication
1 Pylontech Battery
a. 485 Communication
1) For 485 communication, Please set Li 05 on 5th option, L04 on 36th option. On battery dip switch,
please set 1000(ON OFF OFF OFF)
2) 485 Pinout: