Loosen and remove the 8 mm
hex socket Allen Screws (Pos. 28)
connecting the motor stool to Pump
Head (Pos. 2).
Dismantling Procedures CR, CRN 32•45•64•90
Tandem Seal (continued)
Remove the Tandem Seal Housing
O-ring (Pos. 109c).
44
48
8
45
Loosen, but do not remove, the
3 mm Set Screws (Pos. 113)
from the Shaft Seal (Pos. 105).
46
Use two at/slot blade screwdrivers
to pry the seal loose. Lift the seal
completely off the shaft. For seal
change only, go to the Reassembly
section, step 47. To continue
disassembly, proceed to step 48.
Pos. 105
47
Cartridge Seals
Will lift out as a complete assembly.
49
Loosen and remove the 24 mm
Staybolt Nuts (Pos. 36) and Washers
(Pos. 66a).

Other manuals for Grundfos CR 32

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Grundfos CR 32 and is the answer not in the manual?

Grundfos CR 32 Specifications

General IconGeneral
TypeCR
Frequency50/60 Hz
Protection ClassIP55
MaterialStainless Steel
ApplicationsWater supply, pressure boosting
Power ConsumptionVaries by model