Grundfos IO 351 Specifications

General IconGeneral
CategoryI/O Systems
Product TypeI/O Module
ManufacturerGrundfos
Communication ProtocolModbus RTU
Number of Analog Outputs1
Supply Voltage24 V DC
Protection RatingIP20
MountingDIN rail
SeriesIO

Summary

General Information

Hazard Statements

Explains the meaning of hazard symbols and statements used in the manual.

Notes

Explains the meaning of various symbols used for notes and tips.

General Description

Safety Warning

Warns about potential injury if the IO 351 is used in a manner not specified by the manufacturer.

Identification

Type Key

Explains the coding system used to identify different IO 351 product types.

Nameplate Details

Describes the information provided on the product's nameplate for identification.

Installation

Location

Specifies the recommended installation location for the IO 351 module.

Enclosure Class

Details the required enclosure class for protection against pollution.

Terminals

Provides information on the suitability of terminals for different conductor sizes.

Mounting

Step-by-step instructions for mounting the IO 351 on a DIN rail.

EMC-Correct Installation

Allocation of Address

Start-up

Safety and Preparation

Emphasizes using authorized personnel and reading instructions before start-up.

Functions of Indicator Lights

Indicator Status Meanings

Explains the meaning of different indicator light indications on the module.

Technical Data

Environmental and Electrical Conditions

Covers ambient temperature, humidity, pollution degree, and mains supply category.

Electrical Data

Supply and Protection Details

Details supply voltage, back-up fuse, and short-circuit protection requirements.

Digital Inputs Specifications

Specifies characteristics of digital inputs.

Analog Inputs Specifications

Specifies characteristics of analog inputs.

PTC Sensor Inputs Specifications

Specifies characteristics for PTC sensor/thermal switch inputs.

Digital Outputs Specifications

Specifies characteristics of digital outputs (relay).

Analog Outputs Specifications

Specifies characteristics of analog outputs.

Terminal Groups

Overview of Inputs and Outputs

Terminal Designations and Diagrams

Lists terminals, their designation, data, and provides connection diagrams.

GENIbus Terminal Connections

PTC Sensor and GND Terminals

Digital Input and Analog Output Terminals

Digital Output Terminals (Group 5)

GENIbus

Communication Protocol

Explains that CU 351 and IO 351 communicate via GENIbus.

Service

Module Replacement Policy

States the module cannot be serviced and must be replaced if faulty.

Maintenance

Cleaning and Care

Specifies that the module is maintenance-free and how to clean it.

Replacement of IO 351

Step-by-Step Replacement

Provides a step-by-step guide for replacing the IO 351 module.

Dimensions

Dimensional Sketch and Measurements

Provides a diagram with module dimensions and measurements.

Disposing of the Product

Environmental Disposal Guidelines

Instructions for environmentally sound disposal of the product and its parts.