PRE-INSTALLATION
A guide to the EZ Boost System
The EZ Boost Constant Pressure System automatically
balances water surges and equalizes flow and pressure
according to consumption. In other words, the system
maintains a constant water pressure in spite of varying
water consumption. The pressure is registered by means
of the pressure sensor and transmitted to the controller.
ThecontrolleradjuststheEZBoostBMQEpumpperform-
anceaccordingly.The EZBoostConstantPressureSystem
features:
• Quickandeasyinstallation:ready-to-usesystem
requiringminimumspace
• Highuserconvenience:constantpressureregardlessof
waterconsumption
• Easilyadjustablepressurelevel:pushbuttoncontrol
• Continuouscontrolandmonitoringofpumpoperation
• Integrateddry-runningprotection
• Integratedoverloadprotection
• Integratedprotectionagainstovervoltageandunder
voltage
• Softstartsystem
Function
Whenatapisopened,the pressure in thetankwillstart
todrop.Thesystemmaintainsaconstantpressurewithin
themaximumpumpperformanceinspiteofvaryingwater
consumption.
Thepressureisregisteredbymeansofthepressuresensor,
which transmits a signal to the controller. The controller
adjusts the pump performance accordingly to maintain
constantpressurebychangingthepumpspeed.
Atlowflowthepressurewilldropslowly.Whenthepres-
sureinthetankis7PSIbelowthesetpoint,thepumpwill
start. When the pressure is 7 PSI above the setpoint, the
pumpwillstop.
EventhoughtheEZBoostcontrolleriscontrollingthepres-
surewithin±3PSI,largerpressurevariationsmayoccurin
thesystem. If the consumption is suddenly changed, e.g.
if a tap is opened, the water must start flowing before
the pressure can be made constant again. Such dynamic
variations depend on the pipe work, but, typically, they
willliebetween7and14PSI.Ifthedesiredconsumptionis
higherthanthequantitythepumpisabletodeliveratthe
desiredpressure,thepressurefollows the pumpcurveas
illustratedinthefarrightoffig.1.
Fig.1
Atlargeflowrates,thepressurewilldropquicklyandthe
pumpwillstartimmediatelyandmaintainconstantpres-
sure.Whenthesystemisrunning,theEZBoostcontroller
makessmalladjustmentstothepressuretodetectwhether
thereisconsumption.Ifthereisnone,thepumpwillsimply
refillthetankandstopafterafewseconds.
Pressure
Flow
A
Stop
+7PSI
Start
-7PSI
Controlling
±3PSI
Dynamic
variations
±7PSI
GPM0.8
A=Pressuresettin
g
Product Guide EZ Boost
TM
System
24
1
2
Air escape valve
Diaphragm tank
EZ Boost controller
Isolation valve
Pressure gauge
Pressure sensor
BMQE pumps connected in parallel
When connecting BMQE pumps in parallel as shown in
fig.5,a separate EZ Boost controller must be used on each
BMQE. Set the pressure on one BMQE 10 PSI lower than
theother.
For BMQE pumps connected in parallel, mounted above
each other, it is recommended to connect the pipes as
showninfig.5.ThislayoutensuresthattheBMQEpumps
arefilledwithwaterbeforestarting.
Fig.5 BoosterunitwithtwoBMQEpumps
connectedinparallel,mountedaboveeach
other.
Notes:
• AllBMQEmodulesaresuppliedwithanon-return
valve.
• BMQEmodulesconnectedinparallelmayalsobe
installedvertically.
• Asventingproblemsmayariseinsuchinstallations,itis
advisabletoinstallsuitableairventdevices.
• TheBMQEshouldbepositionedwiththedischargeand
airventatthetopwheninstalledvertically.
• WhenthemaximumflowforBMQEpumpsinparallel
will exceed 35 GPM, a 4-gallon or two 2-gallon dia-
phragmtank(s)shouldbeused.