PX/QX/RX Version 4.20 User Manual – Issue B
- 35 -
Appendix C - Log Messages
Alarm & Event Log messages
Log Text Additional Data Display Text Event Description
230v Fault NONE (see note) NONE Mains supply failed
230v OK NONE (see note) NONE Mains supply restored
A
/Set Fault Usnn, Area m Usnn, Am
A
n area auto set with faults
A
ctive Circuit Circuit nnn Cctnnn User selected active circuit test
A
larm Circuit nnn Cctnnn
A
Circuit alarm
A
larm (master shunt) Circuit nnn Cctnnn Master shunt type circuit alarms
A
larm Abort User nn, Keypad m Usnn, KPm
larm abort signal transmitted.
A
nti mask Circuit nnn Cctnnn
A
Circuit program with the anti-
mask option has alarmed
A
uth. Fail User nn Usnn Encryption authentication fail
A
uto Check Fail Circuit nnn Cctnnn
A
Circuit has failed to activate
during the auto check period.
A
uto Check OK NONE NONE Circuit Auto Check was OK
Bat. Restore NONE (see note) NONE The battery voltage is normal
after a battery low
Bat.Monitor Fail NONE (see note) NONE Battery voltage is low or not
present during a battery test
Battery Low NONE (see note) NONE The battery has reached the low
volts threshold (after a mains
fail)
Battery Low Transmitter number TXm Transmitter battery low
Bypass User nn, Circuit mmm Usnn Cctmmm Circuit bypassed
Cannot set User nn, Area m Usnn, Am User was not able to set an area
Cct Tested Circuit nnn Cctnnn Circuit responded in walk test
Changed Code User nn, Keypad m Usnn, KPm User changes own code
Changed Code User nn, User mm Usnn, Usmm Manager or GSR user changes
code for another user
Changed Time User nn, Keypad m Usnn, KPm Time modified, old time and new
time are logged
Check Fuse n N Panel fuse number
Check Fuse Conc n Conc n Concentrator fuse
Check Fuse OPM n OPM n Output module fuse
Check Fuse
A
CM n
A
CM n
A
CM fuse
Clear Circuit nnn Cctnnn Master shunt type circuit clears
Clear Circuit nnn Cctnnn
A
Circuit alarm has cleared.
Code Clash User nn, User mm Usnn, Usmm User has chosen a new code
which is the same as another
user
Comm Acknowledge n N Central station acknowledge
alarm report
Comm Fail NONE NONE Control panel comm fail input
active.
Comm Fail n N Central station fails to
acknowledges alarm report
Comm Fail
Module name Module name
Module has reported a
communications fail
Comm Test User nn, Keypad m Usnn, KPm User or the panel tested the
communicator(s)
Commission Fail User nn Usnn Encryption commission fail
Commissioned User nn Usnn Encryption commission OK
Data Route Fail NONE NONE
A
call using the Dual comm data
route has failed.
Data Route OK NONE NONE
A
call using the Dual comm data
route was successful.
Date Changed Usnn Usnn Date changed (manual or auto)