Operation
Use of GSE 550 DSG (# 4058) – Battery Starting
Fig. 4
Make sure that no appliance is connected to the unit.
x Open the fuel cock by turning it ON
x Switch the engine by on/off.
x Turn the starting key to the “Start“ position (pic. 4)
and pull the d
ecompressio
n lever at the same time.
The gen
erator should start in a few seco
nds. With
the ignition b
eing on, release the decompressi
on
lever agai
n to start the generator
.
CAUTION! If the first starting attempt is
unsuccessful, interrupt starting and make
another attempt. Do not stay more than 5
second in the starting position!
Never remove the battery pole cable at
operation. That
could result in a strong electrical shock.
If the generator is not working after several starting
attempts, the oil pipeline m
ust be manually blown
through.
GSE 550 DSG (#4058) Generator Turning Off
Fig. 5
x Disconnect the appliance from the unit before
stoppi
ng the engine
.
x Close the fuel tap (OFF).
x Turn the fuel cock in (OFF) position.
CAUTION! Always pill the key from the unit
when the generator is out of use and keep it at a
safe place. If the engine is not used for a longer
period of time, it must be switched off, too.
ON
OFF
ON
OFF