GFG-3015 p.41
Abbreviating Commands
Most commands have both long form and short form. The list for each command
in this section shows the abbreviations in upper case. For instance, you can
enter the query
:SOURce:TRIGger:STATe ?
simply as:
:SOUR:TRIG:STAT ?
6.22 The Commands of RS-232 Serial Interface
Common commands
Command Function Parameter
Arguments
*CLS Clear status command None
*IDN? Identification query None
*RCL Recall command <NR1> <0~9>
*SAV Save command <NR1> <0-9>
*RST Default setting
Commands of the instrument
Command Function
Parameter
Arguments
:SYSTem:ERR ?
Check the type of error
messages
None
:FUNCtion:WAVeform
Set the waveform of main
frequency
<NR1> <1>Sinusoid
<2>Triangle
<3>Square
:FUNCtion:WAVeform ?
Check the present
waveform
of main frequency
None
:FREQuency
Set the main frequency
<NRf> Numeric data
:FREQeency ?
Check the main frequency
None
:AMPLitude:VOLTage
Set the value of output
amplitude
<NRf> Numeric data
:AMPLitude:VOLTage ?
Check the value of output
amplitude
None
:AMPLitude:UNIT
Set the unit of amplitude
<NR1> <1>Vpp
<2>Vrms
<3>dBm
:AMPLitude:UNIT ?
Check the unit of amplitude
None
:OFFSet
Set the voltage of offset
<NRf> Numeric data
:OFFSet ?
Check the voltage of offset
None
:DUTY
Set the value of duty
<NR1> Numeric data
:DUTY ?
Check the value of duty
None
:SOURce:WAVeform
Set the waveform of
modulation mode
<NR1> <1>Sinusoid
<2>Triangle
<3>Square