PEL-2000 Series User Manual
58
Voltage and
Current Monitor
Output
The Voltage Monitor Output (VMON) and Current
Monitor Output (IMON) output the load input
voltage and load input current as a percentage of
rating current/voltage. Where 0 volts = 0% rating
and 10 volts = 100% load input rating voltage or
current.
The voltage monitor output is across pins 1 & 3,
and the current monitor output is across pins 1 &
2. Pin 6 outputs a +15V reference voltage.
Below shows the pin configuration of the voltage
and current monitor outputs.
Connector
Connection
The channel control connector is a screw less
clamp connector. The internal clamp mechanism
must be opened before a wire can be inserted. To
open the internal clamp, push the button above the
wire socket, to close, release the button. Ensure at
least 10mm is striped from the wire. The diagram
below shows the wire insertion procedure.
WARNING
All connections to the channel control connector must
use a 24 AWG wire gauge.