CV Mode
Voltage
Time
A value
B value
CV + CC
When using CV mode, a current limit can be set for
CV + CC mode.
When the voltage input is greater than A Value
(load voltage) then the channel will operate in CV
mode if the input current is less than the current
limit. When the input current exceeds the current
limit, the channel will operate in CC mode.
When the voltage input is less than A Value (load
voltage) current stops flowing.