Quick Guide
SOFT Start / StopStart / StopFunction Selection
Press a parameter
(RPM / RCF or TIME) to be changed
PROG Save / Call
Press START / STOP
Press once : CALL / Press countinuous : SAVE
Display & Control Panel
Press up and down
buttons to change and
press PROG button again
to save or call
After setting the
parameters, press
SOFT START / STOP.
When it is started by
SOFT START/STOP
button, press this
button again to stop
the working.
Press up and down buttons to
change and press the buttons
(RPM / RCF or TIME) again to save
Press a parameter (RPM/
RCF or TIME) to be changed
Program SAVE / CALL
Press once : CALL
Press continuous : SAVE (up to 10)
Low-Speed, Clinical Centrifuge
Cat. No. GZ-0416
Door Open
Open : LED turns on
Display Window
Status of Speed
(RPM / RCF)
Setting Speed
Press once : RPM
Press twice : RCF
Start / Stop
LED ON : Start / Run
LED OFF : Stop
Setting Time
To 99 min. 59 sec.
or Continuous (00:00)
Display Window
Status of Time (MIN / SEC)
Program (Call / Save)
Soft Start / Stop (For Sensitive Samples)
LED ON : Soft Start / Run (gentle acceleration)
LED OFF : Soft Stop (gentle deceleration)
It is good for avoiding agitation of
sample during acceleration and
deceleration.
Operation

Other manuals for GYROZEN 416

Question and Answer IconNeed help?

Do you have a question about the GYROZEN 416 and is the answer not in the manual?

GYROZEN 416 Specifications

General IconGeneral
BrandGYROZEN
Model416
CategoryLaboratory Equipment
LanguageEnglish

Summary

Display and Control Panel Overview

Display Windows Functionality

Shows status of speed (RPM/RCF) and time (MIN/SEC) or program status.

Setting Speed and Time

Instructions to set speed (RPM/RCF) and time (MIN/SEC) or continuous operation.

Operational Controls

Functions for starting, stopping, saving/calling programs, and soft start/stop.

Door Open Indicator

Describes the LED indicator status when the centrifuge door is open.

Precautions and Maintenance Tips

Installation and Setup

Remove motor cushion before installation; ensure 30 cm safety zone around unit.

Rotor and Shaft Maintenance

Clean motor shaft and check rotor installation; lubricate contact area for smooth bucket movement.

Cushion Rubber and Balance

Check rotor sleeve cushion rubber direction and balance sample tubes symmetrically.

Shutdown and Storage

Turn off power and unplug cord after operation for cleaning or long-term storage.

Interchangeable Rotors

Lists various interchangeable rotor models compatible with the centrifuge.