9
CT 160 / 210
EN
Translation of the original instructions
TROUBLESHOOTING
Symptoms Causes Remedies
The ON/OFF button does not
switch on when set to ON.
No mains voltage Check that the power cord is plugged to a
230V 50/60Hz socket. Check the power supply
network.
The machine's anmeter does
not uctuate .
Power supply problem. Check your mains power supply.
Clamps in short circuit or polarity
reversal.
Check that the fuses have not melted and that
the circuit breaker is not tripped
The battery that you are trying to
charge is faulty.
Check the terminals' voltage with a voltmeter.
If this voltage jumps instantaneously to 2.5V
per element, the battery may be sulfated or
damaged.
Voltage error (12 -24V) Chck that the switch is on the right setting (12
or 24V)
Following intensive use, your
device has entered thermal
protection mode.
Wait 1/4h so the device can cool down.
The charger is properly
connected but it does not
charge the battery
Blown fuse Replace the fuse by a new one.
Bad clamp connections. Clean the terminals and the clamps. Check the
state of the cables and clamps.
Wrong charge settings Check that the selected voltage matches the
battery voltage.
Following intensive use, your
device has entered thermal
protection mode.
Wait 1/4h so the device can cool down.
The anmeter's pin goes above
the maximum marking while
the device is set to minimum
intensity.
The battery is deeply discharged. Keep charging using the minimum setting .
Voltage error (12 -24V) Chck that the switch is on the right setting (12
or 24V)
Your battery has elements in short
circuit.
Damaged battery Replace the battery.
The fuse blows every time it is
replaced
Polarity reversal Connect the + clamp to the battery's (+) and
the - clamp to the battery's (-).
Starting the vehicle Do not perform any starts when the charger is
connected.
Wrong charge settings Check that the selected voltage matches the
battery voltage.
Current overconsumption on the
battery
Do not draw any of the battery's current during
the charge
The machine is charging a 12V
battery in 24V mode
Set the switch to 12V.
WARRANTY
The warranty covers faulty workmanship for 2 years from the date of purchase (parts and labour).
The warranty does not cover:
• Transit damage.
• Normal wear of parts (eg. : cables, clamps, etc..).
• Damages due to misuse (power supply error, dropping of equipment, disassembling).
• Environment related failures (pollution, rust, dust).
In case of failure, return the unit to your distributor together with:
- The proof of purchase (receipt etc ...)
- A description of the fault reported