EasyManua.ls Logo

H3C S5120V2-LI - User Manual

H3C S5120V2-LI
99 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
H3C S5560S-SI & S5500V3-SI &
S5130S-SI[LI] & S5120V2-SI[LI] &
S5110V2-SI & S5000V3-EI &
S3100V3-SI Switch Series
Installation Guide
H3C S5560S-SI Switch Series
H3C S5500V3-SI Switch Series
H3C S5130S-SI Switch Series
H3C S5130S-LI Switch Series
H3C S5120V2-SI Switch Series
H3C S5120V2-LI Switch Series
H3C S5110V2-SI Switch Series
H3C S5000V3-EI Switch Series
H3C S3100V3-SI Switch Series
New H3C Technologies Co., Ltd.
http://www.h3c.com
Document version: 6W104-20190731

Table of Contents

Questions and Answers

  • T
    Timothy JohnsonAug 7, 2025
    How to troubleshoot input failure on AC-powered H3C S5120V2-LI Switch?
    • M
      Michael RichardsonAug 7, 2025
      To troubleshoot an AC-powered H3C switch that's not receiving power, make sure the AC power cord is properly connected to both the switch and a working AC outlet. Also, ensure the switch's operating temperature is within the acceptable range and that the power module has adequate ventilation. Overheating can trigger a protective shutdown.
  • N
    newtonjenniferAug 12, 2025
    What to do if there is an input failure on an RPS and AC-powered H3C switch?
    • D
      Dustin SmithAug 12, 2025
      If your H3C switch, powered by both RPS and AC, is experiencing input failure, verify that the AC power cord is securely connected to the switch and a functioning AC outlet. Also, check the connection to the RPS and confirm the RPS is operating correctly. Ensure the switch's temperature is within the acceptable range and that the power module has sufficient ventilation.
  • R
    rodriguezchristopherAug 17, 2025
    How to fix no display on the configuration terminal of H3C S5120V2-LI?
    • R
      Richard CampbellAug 17, 2025
      To resolve a missing display on the configuration terminal of your H3C switch, first ensure the power system and the switch itself are working correctly. Verify the console cable is properly connected and not faulty. Finally, confirm that your terminal settings are: Baud rate—9600, Data bits—8, Parity—None, Stop bits—1, Flow control—None.
  • J
    Jenny RodriguezAug 23, 2025
    How to troubleshoot input failure on RPS-powered H3C Switch?
    • L
      leah70Aug 23, 2025
      To troubleshoot an RPS-powered H3C switch that's not receiving power, verify that the switch is securely connected to the RPS and that the RPS is functioning correctly. Additionally, ensure the switch's operating temperature is within the acceptable range and that the power module has good ventilation. Over-temperature can cause the power module to stop working and enter protection state.
  • D
    Diane QuinnAug 27, 2025
    How to resolve garbled display on the configuration terminal of H3C Switch?
    • L
      landersonAug 27, 2025
      To address a garbled display on the configuration terminal of your H3C switch, verify that the terminal settings are configured as follows: Baud rate—9600, Data bits—8, Parity—None, Stop bits—1, Flow control—None.
  • K
    kevingibsonSep 1, 2025
    What to do if hot-swappable power module failure in H3C S5120V2-LI Switch?
    • R
      robertbellSep 1, 2025
      To troubleshoot a hot-swappable power module failure in your H3C switch, ensure that the power module model is the one required and is correctly installed in the switch. Also, verify that the switch is operating within the acceptable temperature range.

Summary

Preparing for Installation

Safety and Site Requirements

Covers safety guidelines, site examination, environmental conditions, and laser safety.

Installing the Switch

Rack Mounting Procedures

Guides on installing the switch in a 19-inch rack, including bracket selection and attachment.

Grounding and Power Connection

Essential steps for grounding the switch and connecting power cords.

First-Time Switch Access

Accessing via GUI

Instructions for accessing and managing the switch via its web-based Graphical User Interface.

Accessing via CLI

Methods for accessing and configuring the switch using the Command Line Interface.

Setting Up an IRF Fabric

IRF Configuration and Connection

Configuring basic IRF settings, connecting physical ports, and verifying the fabric.

Maintenance and Troubleshooting

Appendix C: Ports and LEDs

H3C S5120V2-LI Specifications

General IconGeneral
ModelH3C S5120V2-LI
MAC Address Table Size16K
VLAN Support4K VLANs
Storage Temperature-40°C to 70°C
Operating Humidity10% to 90% (non-condensing)
Storage Humidity5% to 95% (non-condensing)
Switching Capacity176 Gbps
Jumbo Frame9KB
Power SupplyAC 100-240V
Dimensions (W x D x H)440 mm x 260 mm x 43.6 mm
Operating Temperature0°C to 45°C