EasyManuals Logo

H3C UniServer R4950 G5 User Manual

H3C UniServer R4950 G5
401 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #388 background imageLoading...
Page #388 background image
6
Configuring the system to identify the new storage controller
After a replacement, storage controller consistency check might fail if RAID arrays have been built
by using the replaced storage controller. This is because RAID configuration information is saved
on both the storage controller and drives.
The failure might cause the controller to stop operating if the controller's boot mode is set to Stop
on Error. The server cannot identify the new storage controller and the BIOS displays Failed on the
Advanced > Driver Health > AVAGO EFI SAS Driver page.
To solve this issue, perform the following tasks:
1. On the BIOS setup screen, select Advanced > Driver Health > AVAGO EFI SAS Driver, and
press Enter.
2. Select the storage controller, and press Enter.
3. As shown in Figure 7 and Figure 8, enter C or Y as prompted.
Figure 7 Identifying a storage controller (1)