6 English
1 Upper and lower
doors
5 Display and keypad
9 Analytics panel
2 Funnel cover
6 SD card slot
10 Reagent bottle tray
3 Grab sample input
funnel
7 Power switch
11 Colorimeter cover
4 Status indicator light
8 Power LED (on =
analyzer is on)
12 Grab sample valve
protection against harmful interference when the equipment is operated
in a commercial environment. This equipment generates, uses and can
radiate radio frequency energy and, if not installed and used in
accordance with the instruction manual, may cause harmful interference
to radio communications. Operation of this equipment in a residential
area is likely to cause harmful interference, in which case the user will be
required to correct the interference at their expense. The following
techniques can be used to reduce interference problems:
1. Disconnect the equipment from its power source to verify that it is or
is not the source of the interference.
2. If the equipment is connected to the same outlet as the device
experiencing interference, connect the equipment to a different
outlet.
3. Move the equipment away from the device receiving the interference.
4. Reposition the receiving antenna for the device receiving the
interference.
5. Try combinations of the above.
Figure 1 Product overview
Product overview
D A N G E R
Chemical or biological hazards. If this instrument is used to monitor a
treatment process and/or chemical feed system for which there are
regulatory limits and monitoring requirements related to public health,
public safety, food or beverage manufacture or processing, it is the
responsibility of the user of this instrument to know and abide by any
applicable regulation and to have sufficient and appropriate
mechanisms in place for compliance with applicable regulations in the
event of malfunction of the instrument.
The analyzer measures silica concentration in power water and industrial
water. The chemical analysis uses the Heteropoly Blue (molybdenum)
Method, adapted from the Standard Methods.
*
Refer to Figure 1 for the analyzer overview. The doors can be easily
removed for better access. Refer to Figure 2.
*
Standard Methods for the Examination of Water and Wastewater, 21st Edition, 2005, Centennial Edition, APHA, AWWA, WEF, pp 4167, 4500-
SiO
2
D.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hach Polymetron 9610sc SiO2 and is the answer not in the manual?

Hach Polymetron 9610sc SiO2 Specifications

General IconGeneral
BrandHach
ModelPolymetron 9610sc SiO2
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals