When you specify that the event button is activated at the start of the delay by pressing the 1 (START EXIT) key, the mode is
prefixed by "A-" for "arming into".
WHEN AWAY: (END OF DELAY)
WHEN A-AWY: (START OF DELAY)
When the system is armed in the Day (instant) or Night (delay) mode, buttons for the Day and Night modes are executed,
respectively.
- Selecting 2 (CODE) allows you to specify that the event button is activated only when a particular code is used. You will be
prompted to enter the code:
ENTER USER CODE:
1-16 0=ALL
You should enter the user code by entering the code number followed by the ' # ' key or by using the arrow keys to scroll through
a list of code names.
WHEN C1 AWAY:
1=DELAY 2=CODE
WHEN C1 A1 AWAY:
1=START EXIT 2=END EXIT
Zone Event Buttons
Pressing the 3 (ZONE) key allows you to select the event button for a zone activation event. You are first prompted to enter the
desired zone number:
ZONE:
ENTER ZONE
The zone number should be entered followed by the ' # ' key, or the arrow keys may be used to scroll through a list of zones. The
desired zone is then displayed and you are prompted to specify the state that activates the event button:
WHEN Front Door:
0=SECURE 1=NOT RDY
All On/Off Event Buttons
Pressing the 4 (ALL) key allows you to specify an event button activated by issuing an All On or an All Off command, issuing a
Leviton Scene command, or issuing a UPB Link command. You are first prompted to specify whether the event button is for All
Lights On, All Off, Leviton Scene, or UPB Link:
ALL
0=OFF 1=ON 2=SCN 3=LINK
If area arming is being used, you will be prompted to specify the desired area:
AREA:
ENTER AREA 0=ALL
If Leviton Scene is selected, you must first specify the scene number:
ENTER SCENE:
1-64
Then select the specified command Off, On, or Set.
If UPB Link is selected, you must first specify the link number:
ENTER LINK:
1-250