Service diagnosis
32 Domestic air conditioner
10.3.2 EEPROM abnormal
Indoor Display E4: Indoor EEPROM error
Indoor display F12: Outdoor EEPROM error; Outdoor LED1 flash 1 times
Method of The Data detected by the EEPROM are used to determine MCU
Malfunction
Detection
Malfunction When the data of EEPROM is error or the EEPROM is damaged
Decision
Conditions
Suppo
sed
Fa
ulty EEPROM dat
a
C
auses
Faulty EEPROM
F
aulty PCB
Troublesho
oting *
Caution Be sure to turn off power switch before connect or disconnect connector, or part
s
damag
e may be occurred.
Replace the indoo
r or outdoor mainboard.