Do you have a question about the Haier AC35S2SG1FA and is the answer not in the manual?
Guidelines for safely disposing of old air conditioners and packaging materials.
Important safety notes regarding operation, installation, and user conduct.
Details on the refrigerating circuit and required electrical connection methods.
Specifies the operational limits for cooling and heating modes.
Critical safety information on breakers, wiring, and installation hazards.
Precautions for safe operation, including airflow, object placement, and wet hands.
Details on automatic operation for Cooling, Dry, Heating, and Blow modes.
Explanation of the Sleep mode function for cooling and heating operations.
Information on the wireless remote control unit and the mildew-resistant filter.
Identification and description of components on the first operating control panel.
Identification and description of components on the second operating control panel.
Step-by-step guide for removing, cleaning, and re-attaching the air filters.
Recommendations for regular inspection and cleaning of the indoor unit body.
Describes sounds that are normal during operation and not indicative of a problem.
Common operational issues like switching modes or unit not restarting.
Checks for power supply, breakers, and general startup issues.
Checks for operation controls, air filters, obstacles, and room conditions.
Details on outdoor unit error codes, malfunction descriptions, and diagnosis.
Details on more error codes, system protections, and important notes.
Important warnings and cautions for safe and correct installation.
Guidelines for selecting indoor unit location and necessary clearance.
Procedure for removing intake grill, side covers, and connection pipe requirements.
Instructions for cutting intake grill and installing drain and connecting pipes.
Guidance on locating, drilling, and attaching suspension bolts for ceiling mounts.
Steps for lifting and securing the indoor unit and insulating coupler connections.
Instructions for installing the drain hose and connecting wiring to terminals.
Details on solid/strand wiring, electrical requirements, and unit connection.
Wiring diagrams for single and three-phase power and fresh air intake installation.
Checks to perform on the indoor and outdoor units after installation.
Guidance on explaining operation, cleaning, and manual usage to the customer.
This document is an operation and installation manual for a Haier Convertible Type Air Conditioner. It covers various models including AC35S2SG1FA, AC50S2SG1FA, AC71S2SG1FA, AC90S2SH1FA, AC105S2SH1FA, AC125S2SK1FA, and AC140S2SK1FA.
The Haier Convertible Type Air Conditioner is designed for cooling, heating, dehumidifying, and ventilation of rooms in ordinary dwellings. It offers automatic operation modes for both cooling-only and heat & cool types. In automatic cooling mode, the unit selects either cooling or dry mode based on the thermostat setting and actual room temperature. For heat & cool type units, it can operate in heating, cooling, or blow modes automatically.
A "SLEEP" function is available for both cooling and heat & cool models. In cooling or dry mode, when the SLEEP button is pressed, the thermostat setting gradually rises during operation, and the unit automatically turns off when the set time is reached. In heating mode, the thermostat setting gradually lowers during operation, and the unit turns off automatically after the set time.
The unit is controlled by a Wireless Remote Control Unit (YR-H50) for convenient operation. For wired control type units, the unit status is checked via the wired controller.
Refrigerant: The appliance is filled with R32 refrigerant, which has a Global Warming Potential (GWP) of 675. For R410A models, the GWP is 2088. The manual emphasizes that only the specified refrigerant (R32) should be used for installation, moving, or repairing.
Maximum Working Pressure: The maximum working pressure is 4.3 MPa, which should be considered when connecting the outdoor unit to the indoor unit.
Sound Pressure Level: The A-weighted sound pressure level is below 70 dB.
Electrical Requirements:
Temperature and Humidity Range:
Connection Pipe Requirement:
Installation Dimensions:
Controls: The indoor unit features an Operation Control Panel with indicator lamps for RUNNING, TIMER, and POWER, and an Emergency Switch. Some models may have a WIFI Indicator Lamp and a Display Indicator Lamp instead of RUNNING, TIMER, and POWER. A Remote Receiver is also present. For wired control units, the wired controller checks the unit state.
Fresh Air Intake: The air conditioner can be set up for fresh-air intake. This involves opening a knockout hole (top knockout hole for half-concealed installation), fastening a round flange (optional), and connecting a duct, which should then be sealed to prevent air leakage.
Safety Precautions:
Air Filter Cleaning:
Indoor Unit Maintenance:
Troubleshooting: The manual provides a comprehensive troubleshooting guide for common issues and error codes, including:
Disposal:
The manual emphasizes that servicing should only be performed as recommended by the instructions.