Service diagnosis
Domestic air conditioner
27
10.3 Error Codes and Description indoor display
Only For 498 and
498A display
(Red/Green Time
Run OnFlash
Off)
Indoor and
Outdoor
E7 Directly display
15
Communication fault
between indoor and outdoor
units
Page.42
E1 Directly display
/
Indoor temperature sensor
failure
Page.32
E2 Directly display
/ Indoor coil sensor failure Page.32
E4 Directly display
/ Indoor eeprom failure Page.33
E14 Directly display
/ Indoor fan failure Page.34
E5 Trouble record
22
Internal unit antifreeze
protection
/
E9 Trouble record
21 Internal unit overload Page.45
F12 Directly display
1 Eeprom failure Page.33
F1 Directly display
2 IPM failure Page.37
F22 Directly display
3
AC current overcurrent
protection
Page.38
F3 Directly display
4
Communication error
between module board and
main PCB board.
Page.39
F20 Trouble record
5 High pressure protection Page.45
F19 Trouble record
6
Power over/under voltage
protection
Page.40
F27 Directly display
7
Compressor stall / press
instantaneous stop
Page.40
F4 Directly display
8
Compressor discarging
temperature protection
Page.41
F8 Trouble record
9 Abnormal of DC motor Page.36
F21 Directly display
10 Abnormal of piping sensor Page.32
F7 Directly display
11
Suction temperature sensor
failure
Page.32
F6 Directly display
12
Abnormal of outdoor
ambient sensor
Page.32
F25 Directly display
13
Abnormal of compressor
discharge sensor
Page.32
F13 Trouble record
16 Lack of refrigerant /
F14 Trouble record
17 4-way valve reverse failure Page.
F11 Directly display
18
Compressor jam (only for
spdu)
Page.44
F28 Directly display
19
Module PWM select circuit
error
Page.44
F15 Trouble record
20
Outdoor terminal block
temperature protection
Page.
F2 Trouble record
24
Instantaneous over-current
protection of the
compressor
Page.38
F23 Trouble record
25
Compressor U-phase
overcurrent
Compressor V-phase
overcurrent
Compressor W-phase
overcurrent
Page.38
F9 Trouble record
/ 26 Module reset Page.46
F24 Trouble record
27 CT disconnection /
F34 Trouble record
/ 37 Outdoor coil protection /
F35 Trouble record
38
Compressor driver board
failure
/
F43
/ 46
Model matching
abnormality
/
Indoor
Malfunction
Outdoor
Malfunction
fault description Reference Page
Other display
Indoor displaying panel code indication
Code indication
Outdoor
(LED1 flash
times)

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Haier AS105S2SF2FA-2 and is the answer not in the manual?

Haier AS105S2SF2FA-2 Specifications

General IconGeneral
BrandHaier
ModelAS105S2SF2FA-2
CategoryAir Conditioner
LanguageEnglish

Related product manuals