than 90 minutes, when the defrosting sensor malfunction (short circuit or open circuit). 
If defrosting time is more than 90 minutes and the defrosting sensor temperature can’t reach 8ºC, the 
product will disconnect defrosting heater, and display ED on fridge display area under malfunction 
mode until in some defrosting cycle the defrost sensor temperature reach 8 ºC. 
If the product is set to enter into fast freezer or fast fridge, the icon of fast freezer or fast fridge will light, 
but the defrosting process will go on, fast freezer or fast fridge mode will not execute until finishing this 
defrosting cycle. The surplus defrosting time is not reckoned in the time of fast freezer or fast fridge.
 
6-4. Electromagnetic valve