25
Technical Parameters
■ Correction factor
1.CA0035EAND
Cooling:
Water outlet
temperature
(℃)
Ambient temperature (℃)
25 30 35 40 45
kW
Cooling
capacity
Cooling
capacity
Cooling
capacity
Cooling
capacity
Cooling
capacity
5 1.03 0.97 0.94 0.90 0.85
7 1.07 1.03 1.00 0.95 0.88
9 1.10 1.06 1.03 0.98 0.91
11 1.12 1.10 1.08 1.02 0.97
13 1.19 1.20 1.15 1.10 1.05
15 1.31 1.31 1.26 1.20 1.15
Heating:
Water outlet
temperature
(℃)
Ambient temperature (℃)
15 10 7 5 0 -5 -10 -15
kW
Heating
capacity
Heating
capacity
Heating
capacity
Heating
capacity
Heating
capacity
Heating
capacity
Heating
capacity
Heating
capacity
30 1.23 1.15 1.11 1.06 0.87 0.80 0.71 0.62
35 1.13 1.10 1.08 0.83 0.74 0.68 0.58 0.57
40 1.13
1.09 1.05 0.83 0.74 0.66 0.57 0.55
45 1.13
1.09 1.00 0.83 0.74 0.64 0.57 0.53
50 1.13
1.07 0.92 0.81 0.74 0.64 0.56 0.51
55 1.12 1.06 0.92 0.81 0.72 0.62 - -
2.CA0070EAND,CA0100EAND,CA0130EAND
Cooling:
Water outlet
temperature
(℃)
Ambient temperat
ure (℃)
25 30 35 40 45
kW
Cooling
capacity
Cooling
capacity
Cooling
capacity
Cooling
capacity
Cooling
capacity
5 1.07 1.00 0.94 0.94 0.81
7 1.14 1.07 1.00 0.96 0.86
9 1.20 1.13 1.06 0.98 0.91
11 1.27 1.19 1.12 1.04 0.96
13 1.34 1.26 1.17 1.09 1.01
15 1.41 1.32 1.23 1.14 1.06