'RPHVWLF $LU &RQGLWLRQHU
)XQFWLRQV DQG &RQWURO
another hour the temp. setting increase by more 1 and then run continuously for another 6 hours and then ć
close.
5.1.7.2 In heating mode, the temp. setting decrease 2 one hour after start up. After another hour theć
temp. setting decrease by more 2 . After 3 hours the temp. setting rise by 1 and then run continuously for ćć
another 3 hours and then close.
5.1.7.3 If the wind speed is set to high before going to bed, the wind speed become medium after start
up; If the wind speed is set to medium before going to bed, the wind speed become low after start up; If the
wind speed is set to low before going to bed, the wind speed keep unchanged.
5.1.8 Emergency switch input:
5.1.8.1 Press the switch of emergency operation, then buzzer rings once and unit enters the automatic
operation mode. (Emergency operation)
5.1.8.2 If the switch is kept pressed for 5 seconds, buzzer ring two times and unit enter test run mode.
5.1.8.3 Press the switch again, and then closes.
5.1.8.4 Enter emergency operation from timer mode, then timer is cancelled.
5.1.9 Test run:
5.1.9.1 The temperature sensor of inlet air doesn’t work, and compressor starts (but subject to the limit
of minute delay excluding the first time), and high wind, cooling, and air door is open. The indoor fan motor
runs, running indicator lights up, compressor relay and the one of outdoor fan motor is closed.
This operation
lasts 15 minutes
5.1.9.2 During test run:
The prevention of freezing of evaporator doesn’t work.
Temperature control doesn’t work.
Temperature expiration control doesn’t work.
5.1.10 The memory function of power down is available, and the auto recovery function of power on is
optional. (In auto, heating, cooling, or defrosting status, press the “sleeping” button 10 times within 5 seconds,
+6824L/H(A