&RGHVDQGGHVFULSWLRQ
33
E14: Indoor fan motor malfunction
Notes:
When the unit is on, don’t pull out or insert the terminal of the motor (CN26), or else the motor
would be damaged.
NO
Yes
Does fan rotate
smoothly?
NO
Replace fan motor
Yes
Turn power ON and operate fan
Does it rotate?
No
Yes
Turn off power supply and disconnect fan
motor connector, then turn power ON
Check output of fan motor connector
Is motor power voltage
DC310V
enerated?
Yes
NO
Yes
No
Yes
Stop fan motor
Is motor control power
voltageDC15Vgenerat
Is rotation number
command voltage
DC16V
enerated?
Replace indoor unit PCB
No
Replace indoor
fan motor
Turn off power supply and
rotate fan by hand
Replace indoor
unit PCB
Replace indoor
unit PCB
Replace fan
motor
Is rotation number
command pulse
enerated?
+6824L/H(A
Все каталоги и инструкции здесь: http://splitoff.ru/tehn-doc.html