Commercial Air Conditioner Model: HBU-18CF03
HDU-42CF03/H HPU-42HF03
8
Function
coolin
g
heatin
g
Capacity BTU/h
42600 /
Capacity kW
12.5 /
Sensible heat ratio
75% /
W
4700 /
W
5700 /
EER or COP
W/W
2.66 /
Dehumidifying capacity
10³×m³/h
Power cable section
Signal cable section
Connecting cable section
Wired control cable for wired control unit section
/
4×0.33mm²屏蔽线
Power source N, V, Hz
A / A
Start Current A
Class of anti electric shock
I/
Circuit breaker A
/30
Max. operating pressure of heat side Mpa
2.8 /
Max. operating pressure of cold side Mpa
0.8 /
Unit model (color)
Type × Number
Speed(H-M-L) r/min
Fan motor output power kW
Air-flow(H-M-L) m³/h
Type / Diameter mm
Total Area
Temp. scope
External
L×W×H
mm×mm×mm
Package
L×W×H
mm×mm×mm
Air sending angle
//
Drainage pipe (material , I.D./O.D.) mm
Control type (Remote /wired /model)
Fresh air hole dimension mm
Outlet distribution hole dimension mm
kW
dB(A)
kg / kg
External
L×W×H
mm×mm×mm
Package
L×W×H
mm×mm×mm
kg / kg
Unit model (color)
Model / Manufacture
Oil model
Oil type
Oil charging
Type
Protection type
Starting method
Type × Number
Speed r/min
Fan motor output power kW
Air-flow(H-M-L) m³/h
Type / Diameter mm
Row / Fin pitch
Temp. scope
External
L×W×H
mm×mm×mm
Package
L×W×H
mm×mm×mm
Drainage pipe (material , I.D./O.D.) mm
Refrigerant control method mm/mm
Volume of Accumulator L
Noise level dB(A)
material of reduce noise
crankcase heater power W
kg / kg
Type / Charge g
Recharge quantity g/m
Liquid mm
Gas mm
Connecting Method
m
m
4×0.75mm2
SUNISO 4GSDID-K/DAPHNE SE56P
/
1500-1700
0.27
2040
Norminal condition: indoor temperature (cooling): 27DB/19WB, indoor temperature (heating): 20 DB
Outdoor temperature(cooling): 35DB/24WB, outdoor temperature(heating): 7DB/6WB
The noise level will be measured in the third octave band limited values, using a Real Time Analyser calibrated sound intensity meter. It is a
sound pressure noise level. The detailed method please refer to the following information:
1070±30/950±40/860±50/690±50
3380-40050
Indoor unit
HDU-42CF03/H(INDOOR)WHITE
Noise level (H-M-L)
Electricity Heater
cooling 8.2/9.5
50
/
/
cooling: 43~60 / heating: 6~7
1450×980×530
/
1197×828×355
wired
/
item Model
HDU-42CF03/H
5.0
5×2.5mm2
Total power input
Max. power input
Running /Max.Running
Centrifugal × 1
0.156
6000
TP2M / 9.52x0.36
Outdoor unit
HDU-42HF03/H
(
INDOOR
)
WHITE
Weight (Net / Shipping)
62/77
Panel
Dimension
1008×830×480
1130×930×490
2 1.65
cooling: 43~60 / heating: 6~7
Heat exchanger
TP2M / 9.52x0.36
PIPING
R22/3150
/
Pipe
9.52
19.05
Flared
Between I.D &O.
MAX.Drop 30
MAX.Pi
p
in
g
len
g
th 50
Weight (Net / Shipping)
75/85
Type of Four way valve
/
/
Defrosting
Automatic
/
Axial × 1
JT160BCBY1L DAKIN
/
/
硬启动
内置保护器 
/
Capillary tube
Refrigerant
/
/
55/52/47
/
64
740±50
SCROLL
Fan
Heat exchanger
Fan
Dimension
Compressor
Weight (Net / Shipping)
Dimension