Function
coolin
g
heatin
g
Capacity BTU/h
17000 /
Capacity kW
5
/
Sensible heat ratio
75% /
W
1780 /
W
2400 /
EER or COP
W/W
2.81 /
Dehumidifying capacity
10³×m³/h
Power cable section
Signal cable section
Connecting cable section
Wired control cable for wired control unit section
//
Power source N, V, Hz
A / A
Start Current A
Class of anti electric shock
I
/
Circuit breaker A
/30
Max. operating pressure of heat side Mpa
Max. operating pressure of cold side Mpa
Unit model (color)
Type × Number
Speed(H-M-L) r/min
Fan motor output power kW
Air-flow(H-M-L) m³/h
Type / Diameter mm
Total Area
Temp. scope
External
L×W×H
mm×mm×mm
Package
L×W×H
mm×mm×mm
Air sending angle
//
Drainage pipe (material , I.D./O.D.) mm
Control type (Remote /wired /model)
Fresh air hole dimension mm
Outlet distribution hole dimension mm
kW
dB(A)
kg / kg
External
L×W×H
mm×mm×mm
Package
L×W×H
mm×mm×mm
kg / kg
Unit model (color)
Model / Manufacture
Oil model
Oil type
Oil charging
Type
Protection type
Starting method
Type × Number
Speed r/min
Fan motor output power kW
Air-flow(H-M-L) m³/h
Type / Diameter mm
Row / Fin pitch
Temp. scope
External
L×W×H
mm×mm×mm
Package
L×W×H
mm×mm×mm
Drainage pipe (material , I.D./O.D.) mm
Refrigerant control method mm/mm
Volume of Accumulator L
Noise level dB(A)
material of reduce noise
crankcase heater power W
kg / kg
Type / Charge g
Recharge quantity g/m
Liquid mm
Gas mm
Connecting Method
m
m
Norminal condition: indoor temperature (cooling): 27DB/19WB, indoor temperature (heating): 20 DB
Outdoor temperature(cooling): 35DB/24WB, outdoor temperature(heating): 7DB/6WB
The noise level will be measured in the third octave band limited values, using a Real Time Analyser calibrated sound intensity meter. It is a
sound pressure noise level.
750±20/650±30/520±30
1,220-230,50
Indoor unit
HBU-18HF03(INDOOR) (WHITE)
Noise level (H-M-L)
Electricity Heater
8.2/11.0
40
/
570×570×260
REMOTE
0.055
item Model
HBU-18CF03
1.6
3×2.5mm2
Total power input
Max. power input
Running /Max.Running
Centrifugal×1
0.03
2500
/
TH338VEEC MITSUBISHI
3.5/4.5
740×750×115
/
520
inset protector
Outdoor unit
HBU-18CF03
(
OUTDOOR
)
WHITE
Weight (Net / Shipping)
25/27
Panel
Dimension
815×340×680
960×406×750
/
cooling: 43~60 / heating: 6~7
PIPING
R22/1800
/
Pipe
6.35
12.7
Flared
Between I.D &O.
MAX.Drop 5
MAX.Pi
p
in
g
len
g
th 15
Axial × 1
Weight (Net / Shipping)
53/56
Type of Four way valve
/
/
Heat exchanger
/
Refrigerant
Defrosting
Automatic
/
/
45/40/32
/
56
860±30
ROTARY
force start
/
Capillary tube
Fan
Heat exchanger
Fan
Dimension
Compressor
Weight (Net / Shipping)
Dimension
/
3×2.0mm2
2.94
2.94
DIAMOND MS-56
/
/
670
700×700×60
cooling: 43~60 heating:6~7
718×680×380
2. Specification
Commercial Air Conditioner Model: HBU-18CF03
HDU-42CF03/H HPU-42HF03
7