CN7:time-shrink port
CN9:output port of transformer
CN10:swing motor port
CN11:reserved port
CN12:outdoor fan motor port
CN13:compressor port
CN16:neutral wire port
CN17:live wire port
CN18:fan motor port
CN19:neutral wire port
CN20:indoor coil temp. sensor
indoor ambient temp. sensor
CN21:input port of transformer
CN22:control port of network appliance
CN14
:control port of 4-way valve
CN15:water pump port
Dip switch state
BM1(1) BM1(2)
Remark
No outdoor PCB
× ×
The PCB of this
type have not
outdoor PCB
OFF-× ON-√
Unitary free
√ ×
Free multi
× √
Unitary inverter
√ √
Dip switch state BM2(1) BM2(2) BM2(3) BM2(4)
No temperature
compensation
× ×
* *
Temperature compensation
2℃
√ ×
* *
Temperature compensation
4℃
× √
* *
Temperature compensation
6℃
√ √
* *
Cooling only/heating and
cooling
* *
√/×
*
Have/no defrost sensor * * *
√/×
BM3、BM4:set address when used central control
BM4 BM3
Address 1 2 3 4 1 2 3 4
1
× × × × × × ×
2
√ × × × × × ×
3
× √ × × × × ×
4
√ √ × × × × ×
×- no
network
appliance
5
× × √ × × × ×
6
√ × √ × × × ×
……
…… …… …… …… …… ……
126
√ × √ √ √ √ √
127
× √ √ √ √ √ √
128
√ √ √ √ √ √ √
√- have
network
appliance
Commercial Air Conditioner Model: HBU-18CF03
HDU-42CF03/H HPU-42HF03
81