(1) Install insulation for the drain pipe.(See Fig.12 and 13)
Cut the included insulation material to an appropriate size and adhere it to the pipe.
Insulation for Drain pipe
(To be obtained locally.Length
shoud be at least 8mm)
Indoor unit(drain port)
Drain pipe insulation
Drain pipe
Indoor unit
No gap
10mm or over
Drain pipe
Drain pipe insulation
(2) If "Right rear piping ":fasten the drain pipe with VT wires so that the pipe slopes
Fig. 12
Fig. 13
ELECTRICAL WIRING
HOW TO CONNECT WIRING TO THE TERMINALS
(1)Cut the wire and with a wire cutter or wire-cutting pliers,then strip the insulation to about 15/16"(25mm)
of expose the solid wire.
(2)Using a screwdriver ,remove the terminal screw(s) on the terminal board.
(3)Using pliers,bend the solid wire to form a loop suitable for the terminal screw.
B.For strand wiring
(1)Cut the wire and with a wire cutter or wire-cutting pliers,then strip the insulation to about 3/8"(10mm)
of expose the solid wire.
(2)Using a screwdriver ,remove the terminal screw(s) on the terminal board.
A.For solid core wiring (or F-cable)
Indoor unit (rear view)
VT wire
Drain hose
Fig. 14
correctly within
the indoor unit.
-64-
Installation

Other manuals for Haier HBU-42CH03

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Haier HBU-42CH03 and is the answer not in the manual?

Haier HBU-42CH03 Specifications

General IconGeneral
BrandHaier
ModelHBU-42CH03
CategoryAir Conditioner
LanguageEnglish

Related product manuals