EasyManuals Logo

Haier HPE07XC6 User Manual

Haier HPE07XC6
36 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #9 background imageLoading...
Page #9 background image
NO
TE
:
W
ait
for
24
hours
to
turn
on
air
conditioner
if
the
unit
has
been
tilted
for
any
reason.
This
is
for
the
oils
and
the
coolants
to
settle
and
level
off
.
1.
After
a
normal
shut
down
wait
for
3
minutes
before
restarting
the
unit
so
as
to
complete
the
compressor
cycle.
2.
Use
an
115v
/15
amp
outlet
for
the
air
conditione
r
.
Do
not
use
any
other
electrical
appliances
on
this
line
or
you
may
trip
the
fuse.
Use
a
dedicated
line
for
this
air
conditione
r
.
3.
Do
not
place
the
air
conditioner
in
direct
sunlight
or
close
to
any
heating
appliances
(eg
.
baseboard
heaters,
stoves,
etc).
4.
Operate on
a
flat
surface
onl
y
.
5.
K
eep
the
unit
free
of
any
obstructions
such
as
drapes,
curtains,
blinds,
etc.
6.
K
eep
unit
at
least
1
foot
away
from
the
wall.
7.
Check
and
clean
the
filter
once
every
week
for
highest
efficienc
y
.
NO
TE
:
Do
not
use
unit
without
filte
r
.
8.
If
the
unit
is
not
being
used
for
a
long
period
of
time,
remove
the
plug
from
the
water
drain
pipe and
drain
out
any
condensed
wate
r
.
When
turning on
the
unit
for
the
first
time
after
plugging
it into an
electrical
outlet,
the
unit
will
start
in
a
low fan
cool
mode.
The
temperature
reading
out
on
the
LED
will
be
the
current
room
temperature.
When
turning on
the
unit
during
regular
usage,
it
will
remember
the
last
shut
off
set-
ting
.
If
you
want
to
operate
the
air
conditioner
as
a
dehumidifie
r
,
then
adjust
to
dry
mode.
Setting
The
T
emperature
T
o
set
the
temperature,
press
the
+
or
the
-
key
to
raise
or
lower
the
temperature.
The
tempera-
ture
can
be
raised
or
lowered
in
the
cool
or
dry
mode.
The
temperature
cannot
be
adjusted
in
the
fan mode.
Fan
Speeds
There
are
3
adjustable
speeds
in
the
cool
and fan mode:
L
ow
,
Medium &
High.
In
the
dry
or
dehumidification mode
the
fan
will
only
operate
at
low
speed.
On/Off
Time
Set
The
air
conditioner
has
a
1-12
hour
on/off
built
-in
time
r
.
T
o
delay
the
start
time
for
1-12
hours
at
1
hour
intervals,
simply
press
the
time/set
key
and
then
press
the
+
or
-
key
to
adjust
the
start
time.
Note
that
the
unit
has
to
be
plugged
in
to
an
electrical
outlet
for
the
timer
to
operate.
T
o
automatically
shut
-
off
the
unit,
press
the
time/set
key
while
the
unit
is
running and
then
press
the
+
or
-
key
to
adjust
the
shut
-
off
time.
The
auto
shut
-
off
switch
operates
in
all
3
modes:
Cool,
Dry
&
F
an.
NO
TE
:
The
temperature
can
be
set
between
60˚F
to
89˚
F
.
8

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Haier HPE07XC6 and is the answer not in the manual?

Haier HPE07XC6 Specifications

General IconGeneral
BrandHaier
ModelHPE07XC6
CategoryAir Conditioner
LanguageEnglish

Related product manuals